| PLANE ANGLE AND FORM & SURFACE ROUGHNESS
LABORATORY |
|
| |
|
|
|
| |
|
|
|
| |
|
|
Quantity - plane angle and deviation from straightness.
|
| |
|
|
Unit - °, ´, µm.
|
| |
|
|
Tasks
- the main task is the
realisation and maintenance of the plane angle standard. |
| |
|
|
|
| |
|
|
International
comparisons |
| |
|
|
EUROMET 371, CCL-K3.
|
| |
 |
Available
metrological services |
| |
|
|
| Calibration
or Measurement services |
Measurand
Level or Range |
Expanded
uncertainty (k=2) |
| Optical
polygons |
up to
72-sides |
>/=
0.1'' |
| Angle
blocks; pentagonal prism |
0° ÷
360° |
>/=
0.2'' |
| Rotary
tables and heads; goniometers |
0° ÷
360° with step 5° |
>/=
0.2'' |
| Theodolits |
horizontal
scale with step 5° |
>/=
0.2'' |
| Autocollimators |
0° ÷
2° 30' |
>/=
0.1'' |
| Angle
encoders with determination of flexible coupling
errors |
0° ÷
360° with step 5° |
>/=
0.2'' |
| Clinometers |
0° ÷
360° with step 5° |
>/=
0.2'' |
| Level
of all kinds |
0° ÷
2° 30' |
>/=
0.1'' |
| 90°
squares of all form (rectangle, cylinders, etc.) |
up to
length 1100 mm |
angle:
>/= 0.5'' |
| straightness:
>/= 0.2 µm |
| Straightness |
in
vertical plane, up to length 1100 mm |
>/=
0.2 µm |
|
| |
|
|
|
| |
 |
Instuments
in use |
| |
|
|
 |
The
National Standard of Plane angle consists of the
following devices and artifacts: Laser goniometer
GS1L (Arsenal, Kiev, Ukraine), the standard
device EZB-3 (ČSMÚ, Bratislava), adapted small angle
generator TA 48 (Hilger & Watts, England) and set of
standard polygons. |
| Calibration
of optical polygons is performed with the laser
goniometer GS1L (using a ring laser for realisation of
the angular scale). |
| All kinds of
autocollimators and levels are calibrated on the adapted
small angle generator TA 48. |
| The angle
ancoders are calibrated at the standard device EZB-3 by
comparison with the standard polygons. |
| |
|
|
All the
devices with angle scale (tables, heads, goniometers,
etc.) are calibrated by standard polygons and
autocollimator. |
| |
|
|
The angle
blocks and pentagonal prisms are calibrated by the
optical method on laser goniometer GS1L. |
| |
|
|
All squares
are calibrated on the standard device NME 90° using a
comparison with the standard square. |
| |
|
|
|
| |
|
|
|